Wire resistance calculator online
Calculate conductor resistance and voltage drop from material, length, and cross-section. Include conductor temperature, load current, and supply voltage to assess a line.
01 / Calculation method
Electrical resistance depends on the conductor’s material resistivity, length, cross-sectional area, and operating temperature. This calculator evaluates line parameters using standard electrical engineering equations.
Calculation steps
1. Conductor geometry
Depending on the selected input mode, the calculator determines the cross-sectional area in mm² or the conductor diameter in mm. If the area is specified, the diameter is:
If the diameter is specified, the equivalent cross-sectional area is:
where .
2. Temperature effect on resistance
The electrical resistivity of metals increases as they heat up. If temperature correction is enabled, resistivity in Ω·mm²/m at temperature in °C is:
where:
- is the material resistivity at 20 °C: 0.0175 Ω·mm²/m for copper and 0.0283 Ω·mm²/m for aluminum;
- is the temperature coefficient of resistance: 0.00393 1/°C for copper and 0.00403 1/°C for aluminum;
- is the conductor operating temperature in °C.
If temperature correction is disabled, resistivity at 20 °C is used: .
3. Electrical resistance and conductance
-
Resistance of one conductor of length in meters:
-
Resistance per meter of line:
-
Out-and-back loop resistance for two conductors in a single-phase line, phase and neutral:
-
Conductance of one conductor, the reciprocal of resistance:
4. Voltage drop and power losses
When voltage-drop calculation is enabled, the calculator uses the specified load current in A and supply voltage in V to find:
-
Voltage drop along the line:
-
Relative voltage drop as a percentage of nominal supply voltage:
-
Active power loss dissipated as heat in the line conductors:
02 / Frequently asked questions
Why account for wire temperature when calculating resistance?
As a metal heats up, thermal vibrations in its crystal lattice make it harder for free electrons to move. Resistance therefore rises, increasing energy losses and voltage drop along the line. Accounting for operating temperature improves the estimate for an electrical network.
Why calculate loop resistance instead of just one conductor?
Current flows from the source to the load through the phase conductor and returns through the neutral in a single-phase circuit. It therefore travels the full cable length twice. Voltage drop and heat losses are based on the out-and-back loop resistance: .
How is wire resistance related to its cross-sectional area?
Electrical resistance is inversely proportional to conductor area: doubling the cross-section halves the resistance. A larger cross-section reduces voltage drop at the end of the line and lowers conductor heating.
Can I use this calculation to choose a cable size?
The calculator estimates the conductor’s physical and electrical properties. Cable sizing for installation must also account for installation conditions, permissible continuous current, short-circuit current, and applicable electrical rules or standards.