Concrete strength development calculator online
Calculate concrete strength development online. Enter the required dimensions and parameters to estimate quantities and key values.
01 / Calculation method
Concrete strength development calculation
The calculator estimates the developed share of strength and the compressive strength of concrete based on curing age, average ambient or mass temperature, and the selected EN 206 concrete class. It supports engineering review of hardening in cast-in-place concrete and reinforced concrete, preliminary formwork timing, and construction sequencing.
It reports the percentage of the 28-day reference strength as well as estimated cylinder and cube strengths in MPa.
Calculation steps
1. Concrete properties and curing conditions
The initial inputs are the concrete class under EN 206, concrete age in days, and average curing temperature in °C. The selected class provides the reference cylinder strength and cube strength .
2. Concrete class factor
A class adjustment factor is used to account for cement hydration kinetics at different strength grades:
The factor is for C12/15, for C16/20, for C20/25, for C25/30, for C30/37, for C35/45, and for C40/50.
3. Temperature factor for strength development
The average curing temperature selects a base temperature factor representing faster or slower hydration:
The table covers average temperatures from () to ().
4. Strength development percentage
The strength development percentage follows a logarithmic time relationship:
The result is limited to the physical range from to :
The formula reflects rapid early strength gain that gradually slows toward 28 days.
5. Estimated cylinder strength
The estimated characteristic cylinder strength at age days is:
Here, is the reference cylinder strength in MPa for the selected class (for example, for C25/30).
6. Estimated cube strength
The estimated cube strength is calculated in the same way:
Here, is the reference cube strength in MPa (for example, for C25/30).
Standards referenced
The calculation follows principles from these European standards:
- EN 206: Concrete — specification, performance, production and conformity.
- EN 1992-1-1 (Eurocode 2): Design of concrete structures.
- EN 13670: Execution of concrete structures.
02 / Frequently asked questions
Why does the calculator show both a percentage and strength in MPa?
The percentage estimates the share of the specified concrete strength reached by the selected time. Estimated strength in MPa is useful for comparison with project requirements, laboratory tests on cube or cylinder specimens, and construction procedures.
Why does temperature have such a strong effect on concrete hardening?
Concrete strength development depends on cement hydration, whose rate is directly affected by the curing temperature. At a higher average temperature, the hydrothermal reactions proceed faster and early strength develops more rapidly. Lower temperatures slow hardening considerably.
Why is 28 days used as the reference age?
In international and European construction practice (EN 206 and EN 1992-1-1), 28 days is the standard reference age for specifying concrete strength class at a curing temperature of +20 °C. The calculator relates its current estimate to this reference age.
Can I use this calculation to decide when to remove formwork?
The calculator provides an approximate view of strength development and helps compare curing temperature scenarios. A formwork removal decision must also consider the required stripping strength for the specific member, its loading, curing conditions, and actual on-site strength checks under EN 13670.
What is the difference between cylinder and cube strength?
These are compressive strength values measured on specimens with different shapes: cylinders 150 mm in diameter and 300 mm high, or cubes with 150 mm sides. Confinement and stress distribution make cube strength numerically higher than cylinder strength. In the EN 206 system, both values appear in a concrete class; for example, C25/30 means for the cylinder and for the cube.