Strip foundation calculator online

Calculate strip foundation online. Enter the required dimensions and parameters to estimate quantities and key values.

DOC_REF // CALC-STRIP-FOUNDATION

Wall layoutEnter the value using the units shown. Check the measurements before calculating.

Foundation dimensions

Width strips

Additional calculations

Enter the value using the units shown. Check the measurements before calculating.
Enter the value using the units shown. Check the measurements before calculating.
Diagram foundation

Geometry Title

Outer perimeter0 m
Side Area0 m²
footing Area0 m²
Main strip0 m
inner Length0 m
Total length0 m
Volume main strips0 m³
Internal volume0 m³
Total Volume0 m³

Results are estimates. Check the dimensions and verify the design against local requirements before construction.

01 / Calculation method

About the strip foundation calculation

The strip foundation calculator provides a preliminary estimate of the monolithic strip length, concrete volume, footing area, exterior side surface, formwork boards, and approximate rebar length. It is useful for quickly estimating materials for a private house, extension, garage, or outbuilding when comparing wall layouts.

The results are approximate. Before ordering concrete, rebar, or lumber, verify the foundation geometry, soil conditions, loads, strip cross-section, and reinforcement against the design and applicable building codes.

Strip geometry

The calculator first determines the calculated length of the exterior outline from building dimensions AA and BB. For a rectangular layout, it uses the centerline length of the assembled strip:

Lout=2⋅(A+B)−4⋅toutL_{out}=2\cdot(A+B)-4\cdot t_{out}

where LoutL_{out} is the main strip length in mm, AA and BB are the exterior foundation dimensions in mm, and toutt_{out} is the main strip width in mm. Subtracting 4⋅tout4\cdot t_{out} converts the exterior dimensions to the centerline geometry of the monolithic strip.

If an interior-wall layout is selected, the calculator determines the partition length LinL_{in} separately. Its value depends on the clear interior dimension, offset ABAB, or number of interior lines for the selected layout. If load-bearing wall C is selected, that segment is treated as part of the main strip and uses its width.

The total calculated length is the sum:

Ltotal=Lout+LinL_{total}=L_{out}+L_{in}

Concrete volume and areas

Concrete volume is calculated separately for the main strip and interior partitions because their widths may differ:

Vout=Lout⋅tout⋅H1 000 000 000V_{out}=\frac{L_{out}\cdot t_{out}\cdot H}{1\,000\,000\,000} Vin=Lin⋅tin⋅H1 000 000 000V_{in}=\frac{L_{in}\cdot t_{in}\cdot H}{1\,000\,000\,000} Vtotal=Vout+VinV_{total}=V_{out}+V_{in}

where HH is the strip height in mm and tint_{in} is the width of the interior strips in mm. Dividing by 1 000 000 0001\,000\,000\,000 converts cubic millimetres to cubic metres.

The footing area is an approximate measure of the foundation area bearing on the ground:

Afoot=Lout,m⋅tout,m+Lin,m⋅tin,mA_{foot}=L_{out,m}\cdot t_{out,m}+L_{in,m}\cdot t_{in,m}

Exterior side surface is calculated from the building’s outer perimeter and strip height:

Aside=2⋅(Am+Bm)⋅HmA_{side}=2\cdot(A_m+B_m)\cdot H_m

Formwork calculation

When formwork calculation is enabled, the calculator estimates both sides of all strips using the specified panel height:

Afw=2⋅Ltotal⋅HfwA_{fw}=2\cdot L_{total}\cdot H_{fw}

The number of board courses is the formwork height divided by the board’s working width, rounded up:

Nrows=⌈Hfwb⌉N_{rows}=\left\lceil\frac{H_{fw}}{b}\right\rceil

Total board length is:

Lboards=2⋅Ltotal⋅NrowsL_{boards}=2\cdot L_{total}\cdot N_{rows}

The number of boards is found by dividing the total length by the length of one board and rounding up. Lumber volume is calculated as the board area multiplied by its thickness.

Longitudinal rebar calculation

Longitudinal rebar is based on the full strip length and the specified number of longitudinal bars in the cross-section. Lap length is:

llap=40⋅dl_{lap}=40\cdot d

where dd is the longitudinal bar diameter in mm. For example, a 12 mm bar has a calculated lap of 480 mm.

If one bar cannot cover the full line, the calculator adds additional bars with laps. The total longitudinal rebar length is:

Lrebar=(Ltotal+Njoints⋅llap)⋅nL_{rebar}=(L_{total}+N_{joints}\cdot l_{lap})\cdot n

where nn is the number of longitudinal bars in the strip and NjointsN_{joints} is the number of joints along one longitudinal line.

Stirrups

Stirrup dimensions are based on the reinforcement cage’s inner outline. The concrete cover is subtracted from both sides of the strip width and height:

tc=t−2⋅ct_c=t-2\cdot c Hc=H−2⋅cH_c=H-2\cdot c

One stirrup’s length is taken as the inner perimeter plus a lap equal to the inner width:

lst=2⋅(tc+Hc)+tcl_{st}=2\cdot(t_c+H_c)+t_c

Stirrups are calculated separately for the main strip and partitions if their widths differ. Their count along the strip is:

Nst=⌈Ls⌉+1N_{st}=\left\lceil\frac{L}{s}\right\rceil+1

where ss is the stirrup spacing. The calculator then estimates how many straight bars of the specified length are needed to make all the stirrups.

Practical notes

The calculation shows the geometry and an approximate material schedule, but it does not replace a structural design. A real foundation requires checks of soil bearing capacity, founding depth, frost heave, concrete class, cover, rebar diameter and spacing, intersections, and starter bars.

Material orders commonly include an allowance for rebar trimming, corner laps, formwork assembly losses, uneven trench sides, and actual concrete placement. Check the design especially carefully for weak soil, heavy walls, changes in elevation, and foundations supporting critical structures.

02 / Frequently asked questions

Why is the concrete volume calculated separately for the main strip and partition strips?

The exterior strip and interior partition strips can have different widths. The calculator first determines the length of each group, then multiplies it by the corresponding width and height. It adds the concrete volume for the exterior outline and partition strips to produce the total.

Why is the side surface area not the area of every foundation face?

The results show the exterior side surface along the foundation’s outer perimeter. Interior partition strips are not included. This value is useful for a preliminary estimate of exterior waterproofing, plinth insulation, or finishing the visible part of the concrete strip.

Why are the numbers of boards and reinforcing bars rounded up?

Foundation materials are purchased as whole items: boards, formwork panels, rebar lengths, and stirrups. The formwork and rebar calculator therefore rounds quantities up so a fractional result does not leave you short on site.

How does the length of a reinforcing bar affect the result?

The length of one bar affects the number of longitudinal rebar joints and the total amount of steel. If a bar is shorter than the calculated strip length, the calculator adds a lap of 40 bar diameters. Short bars require more joints, which increases the total rebar length.

Can I use this calculation to size a foundation for the soil and building loads?

No. The strip foundation calculator is intended to estimate concrete, rebar, formwork, and exterior side area. The strip width, height, and founding depth must be confirmed by an engineering design based on soil conditions, building loads, settlement, and bearing capacity.

Which matters more for accuracy: house dimensions or the layout of the interior walls?

Both matter. The house dimensions determine the foundation’s exterior perimeter, while the selected interior-wall layout adds the length of partition strips. If that layout differs from the actual floor plan, concrete volume and rebar quantities will only be approximate.

What material allowance should I add after the calculation?

For concrete, add a small allowance for uneven trench sides, formwork movement, and placement losses. The allowance for boards and rebar depends on the cutting plan, supplied lengths, and number of joints. Before ordering, compare the estimate with the actual reinforcement and formwork layout.