Heating radiators calculator online
Calculate heating radiators online. Enter the required dimensions and parameters to estimate quantities and key values.
01 / Calculation method
Heating radiator sizing estimate
The calculator estimates a room’s required heat output and selects the number of radiator sections or steel panel radiators. It accounts for floor area, ceiling height, design winter temperature, target indoor temperature, window quality and glazing area, insulation, number of exterior walls, space above, air changes, system temperature regime, and radiator connection type.
Results are approximate. A heating design must also check heat loss through the envelope, system hydraulics, actual radiator output from its data sheet, and local requirements.
Room geometry
Room volume is area multiplied by ceiling height:
where is volume in m³, is room area in m², and is ceiling height in meters.
Temperature difference for heat-loss calculations is:
where is the desired indoor temperature and is the design outdoor winter temperature.
Room heat loss
The base transmission heat loss is based on floor area and correction factors:
The selected heat-loss level sets . Typical values are about 100 W/m² for an older or poorly insulated building, 80 W/m² for a standard building, 60 W/m² for a modern insulated home, and 45 W/m² for an energy-efficient home. You can enter a known design value. Factors account for glazing, insulation, exterior walls, the space above, and room orientation.
Ventilation and infiltration losses are calculated separately:
where is air changes per hour. The calculator offers scenarios from minimal infiltration to ordinary housing, leaky old windows, active ventilation, and heat recovery. A heat recovery unit reduces ventilation heat loss, so the calculator uses a lower effective air-change rate. Total required heat output is:
Adjusting radiator output
Rated radiator output depends on the system temperature regime. The calculator finds logarithmic mean temperature difference:
where is flow temperature and is return temperature. If the flow and return temperature differences relative to the room are nearly equal, an ordinary average temperature difference is used to avoid division by a value close to zero. Effective output of one section or panel radiator is:
The current version uses , a typical factor for preliminary adjustment of sectional and panel radiators. Connection factor accounts for the connection layout. Diagonal connection is the baseline; bottom and other less favorable connections reduce estimated output.
Number of sections or radiators
The number of units is rounded up:
For bimetallic, aluminum, and cast-iron radiators, is the number of sections. For steel panel radiators, it is the number of complete radiators at the selected rated output.
Practical limits
The calculator provides a quick online radiator output estimate, but does not model exact wall materials, thermal bridges, window recesses, screens, curtains, actual heat-carrier flow, or system balancing. If the result is near a threshold, compare several radiator sizes and confirm that the selected unit suits the real installation conditions.
02 / Frequently asked questions
Why is the number of radiator sections rounded up?
A radiator cannot be installed or purchased as a fraction of a section, and a panel radiator is also a whole unit. The calculator divides the room’s required heat output by the effective output of one section or radiator and rounds up so the heating capacity is not below the estimated load.
Why does radiator output differ from its rated output?
Manufacturers state output for a specified temperature regime. If the system uses lower flow and return temperatures, the radiator emits less heat. The calculator adjusts nominal output using the temperature difference.
Which should I choose for a typical apartment: bimetallic, aluminum, or steel?
For a preliminary calculation, the key inputs are the rated output of a section or radiator and the system temperature regime, rather than the material alone. Bimetallic and aluminum radiators are calculated by sections; steel panel radiators are whole units. Final selection depends on pressure, water quality, installation location, and heating system requirements.
Why does a corner room need more heat output?
A corner room usually has two exterior walls and more surface exposed to outdoor conditions. It loses more heat, so the calculator increases the estimated load using the exterior-wall factor.
Can I size radiators using only the 100 W per m² rule?
The 100 W/m² rule is useful for a rough estimate, but does not account for ceiling height, regional climate, windows, insulation, or ventilation. This calculator uses it as a baseline and adjusts for the selected room conditions.
Should I account for the radiator connection type?
Yes. Diagonal connection usually distributes heat more evenly. Bottom or otherwise unfavorable connections can reduce actual output, so the calculator applies a correction factor to section or radiator power.