Straight stairs with closed stringers calculator online

Calculate straight stairs with closed stringers online. Enter the required dimensions and parameters to estimate quantities and key values.

DOC_REF // CALC-STRAIGHT-STAIRS-WITH-CLOSED-STRINGERS

Type stairs

Dimensions opening

Steps

Section Stringer

Options

Enter the value using the units shown. Check the measurements before calculating.
Enter the value using the units shown. Check the measurements before calculating.
Enter the value using the units shown. Check the measurements before calculating.
Node steps
Drawing Side View
Top view
Drawing Stringer

Length opening L, mm0
Height H, mm0
flight Width, mm0
Steps0

Geometry

Slope angle0
riser Height0
going0
tread Depth0
Check the entered values and units, then try again.-
riser Count0
Height top steps0

Materials

Tread length0
support Elements0
Stringer Step0
Stringer Top0
Stringer Bottom0

Results are estimates. Check the dimensions and verify the design against local requirements before construction.

01 / Calculation method

Closed stringer staircase calculation

The closed stringer staircase calculator determines the geometry of a straight flight from the opening length, rise, stair width, and number of steps. It helps estimate the stair pitch, riser height, going, stringer dimensions, tread and riser dimensions, and handrail length.

The results are approximate. Before building the stairs, check step comfort, stringer bearing, connections, guardrails, and project requirements.

Main formulas

The number of rises depends on the top-step arrangement:

N=n+1N = n + 1

where nn is the number of visible treads. The top tread of a closed stringer staircase is always below the upper floor level.

The rise height is:

h=HNh = \frac{H}{N}

The horizontal going is:

a=Lna = \frac{L}{n}

The structural tread depth, including the nosing and riser, is:

b=a+c+trb = a + c + t_r

where cc is the nosing and trt_r is the riser thickness, when risers are included.

The stair pitch is:

α=arctan⁡(ha)\alpha = \arctan\left(\frac{h}{a}\right)

The step length along the sloping stringer is:

s=h2+a2s = \sqrt{h^2 + a^2}

The stringer blank length is:

ltetiva=Hsin⁡αl_{tetiva} = \frac{H}{\sin\alpha}

where HH is the total stair rise.

Practical guidelines

For residential stairs, a riser of about 150–200 mm and a going of about 270–320 mm are common targets. A pitch of 30–40° is usually considered comfortable for everyday use. If the pitch is too steep, consider increasing the opening length or changing the number of steps.

In this calculator, stair width is also used as the length of each tread. Residential stairs are often 800–1000 mm wide, but the final value depends on the layout and required passage width.

The calculator creates four drawings: a step detail, a side view of the flight, a plan view, and the stringer layout. All drawings use the same input data as the results.

02 / Frequently asked questions

Where is the top step of a closed stringer staircase located?

The top step is below the finished floor level of the upper story. One additional rise takes you from that step up to the finished floor.

How does going differ from tread depth?

Going is the horizontal distance between adjacent risers. The tread depth including the nosing is greater because it includes the front overhang and, for a closed staircase, the riser thickness.

How should I choose the number of steps?

Choose a number that gives a comfortable rise. Residential stairs often use a rise of about 150–200 mm, but the final choice depends on the floor-to-floor height and the available stair opening.

What do the four drawings show?

The step detail shows the nosing, tread thickness, and riser. The side view shows the flight, its angle, and the stringer. The plan view shows the stair width and tread layout. The stringer layout shows where to mark the tread recesses on the supporting board.

Can I use the calculation as a construction design?

No. The calculator provides geometry and approximate blank dimensions. Check load capacity, connections, guardrails, and code compliance separately.