Steel canopy frame calculator online
Calculate steel canopy frame online. Enter the required dimensions and parameters to estimate quantities and key values.
01 / Calculation method
How the steel canopy frame calculation works
The steel canopy calculator performs a preliminary section selection for the frame beam, columns, and purlins. You can select a rectangular or round hollow section, an I-beam, a channel, or an angle for each member; the calculator then chooses the smallest matching section from its built-in range. It is intended for comparing options for a small, single-level canopy with two columns in a plane frame. The result is not a construction design: foundations, connections, three-dimensional bracing, snow drifts, and local code requirements must be checked separately.
Loads and structural model
Snow and permanent loads are applied to the horizontal projection of the roof. The strength check uses factors of for snow and for permanent load:
where is the snow load, is the permanent load, and is the canopy length. The beam is modeled as simply supported with a uniformly distributed load. Its maximum bending moment is:
Purlins are also modeled as simply supported. The load on one purlin is based on a roof strip of width , where is the number of purlin bays. Wind is treated separately as a horizontal load on the frame; for the preliminary column check, its moment is taken at mid-height.
Section selection and checks
For hollow and round sections, the calculator determines the area, second moment of area, and section modulus. For I-beams, channels, and angles, it uses values from the built-in section range:
Bending stress is compared with the design resistance :
Beam and purlin deflection under a uniformly distributed load is calculated as:
where MPa. The calculator selects the first section in its built-in range that satisfies both the strength check and the selected deflection limit of , , or . If even the largest section fails, the calculator reports this; the result should not be treated as a valid section selection.
The column is also checked for the combined effect of axial compression from vertical loads and bending from wind. The stability factor is determined from the nondimensional slenderness , and the utilization combines the compression and bending terms:
02 / Frequently asked questions
Can I buy the steel sections based on the result?
No. This calculator is for preliminary sizing. Before installation, an engineer should check the structural model, connections, supports, out-of-plane frame stability, and actual regional loads.
Why aren’t wind and snow combined in one check?
In this preliminary model, snow and permanent loads are combined to check the beam and purlins as vertical loads. Wind is checked separately as a bending moment in the column. The full load combinations depend on the applicable code, canopy shape, and restraints.
What does the number of purlin bays mean?
It is the number of equal roof-covering strips between adjacent frames. Increasing this number reduces the tributary area, load, and bending moment on each purlin.