01 / Calculation method
Wall dew point calculation
The dew point calculator estimates the risk of interstitial condensation in a multilayer building envelope using a simplified steady-state Glaser-type method. It displays temperature and water-vapor partial-pressure profiles through the assembly thickness.
Use it to compare wall or roof build-ups and identify which layer or interface may develop a possible condensation zone under the selected indoor and outdoor conditions.
Temperature profile
Thermal resistance of a layer. For each layer, thermal resistance is calculated from thickness in meters and thermal conductivity :
where is layer thickness in meters and is conductivity in W/(m·K).
Surface resistances. Standard inside and outside surface resistances and account for heat exchange with the surrounding air:
Total thermal resistance. The assembly resistance is:
Temperature at layer interfaces. For indoor temperature and outdoor temperature , temperature at each interface is proportional to the cumulative thermal resistance from the inner surface:
where is cumulative thermal resistance from the indoor environment to position .
Saturation vapor pressure
At each point, the temperature determines the maximum water-vapor pressure in the pore air without condensation, the saturation pressure in Pa. The calculator uses a standard temperature-dependent saturation function.
Water-vapor partial pressure
Partial pressure at the boundaries. Indoor and outdoor partial pressures are calculated from relative humidity and saturation pressure at the corresponding temperature:
Diffusion resistance of a layer. For each layer, vapor diffusion resistance is calculated from thickness and vapor permeability :
where is entered in mg/(m·h·Pa), so is in (m²·h·Pa)/mg.
Surface diffusion resistances. Constant additions account for boundary air layers at the assembly surfaces:
Total vapor diffusion resistance:
Distribution through the assembly. Actual partial pressure at each interface is interpolated linearly according to the fraction of cumulative diffusion resistance:
Condensation criterion
Water vapor may condense at any point if actual partial pressure is greater than or equal to saturation pressure at the same temperature:
Any part of the assembly where this condition is met is marked as a possible condensation zone.
02 / Frequently asked questions
What does the possible condensation zone on the chart mean?
It is a part of the assembly where calculated water-vapor partial pressure is greater than or equal to saturation pressure at that temperature (). Air in the material pores is saturated with moisture there, so vapor may condense into liquid water.
Why look at temperature and partial pressure together?
Moisture condensation depends on the balance between heat and vapor. Wall temperature determines the maximum saturation pressure (red curve), while vapor permeability and layer thickness determine actual vapor pressure (green curve). Comparing both curves helps assess whether the assembly remains dry.
Why does condensation risk often occur near the cold side?
Near the outside surface, wall temperature falls and saturation pressure drops sharply. If inner layers allow vapor through while outer layers resist it, actual partial pressure falls more slowly than , and the curves can cross.
Is this calculation fully accurate for a real house?
The calculator uses a simplified steady-state Glaser-type method. It is useful for quickly comparing wall or roof build-ups. Real temperature and humidity fluctuate, and wind, sun, and wind-driven rain affect the assembly; transient methods such as EN 15026 model these effects more accurately.
How can I reduce condensation inside a wall?
A common design principle is for vapor permeability in a multilayer wall to increase from inside to outside, while thermal resistance increases toward the exterior. This helps vapor escape outdoors instead of becoming trapped in cold parts of the assembly.