Wall dew point calculator online

Calculate wall dew point online. Enter the required dimensions and parameters to estimate quantities and key values.

DOC_REF // CALC-WALL-DEW-POINT

Layers

layer 1
layer 2
layer 3

Installation conditions

23
-14
chart Title

Result Thermal Result-
Result Vapor Result-
Result Condensation-
Result Indoor Temperature Limit-
Result Dew Point Indoor-

Section Material Props

Table NumberMaterialThickness, mmDensity ρ, kg/m³Thermal conductivity λA, W/(m·To)Thermal conductivity λB, W/(m·To)Table Permeability, Pa
1------
2------
3------
4------
5------

01 / Calculation method

Wall dew point calculation

The dew point calculator estimates the risk of interstitial condensation in a multilayer building envelope using a simplified steady-state Glaser-type method. It displays temperature and water-vapor partial-pressure profiles through the assembly thickness.

Use it to compare wall or roof build-ups and identify which layer or interface may develop a possible condensation zone under the selected indoor and outdoor conditions.

Temperature profile

Thermal resistance of a layer. For each layer, thermal resistance is calculated from thickness dd in meters and thermal conductivity λ\lambda:

Ri=diλiR_i = \frac{d_i}{\lambda_i}

where did_i is layer thickness in meters and λi\lambda_i is conductivity in W/(m·K).

Surface resistances. Standard inside and outside surface resistances RsiR_{si} and RseR_{se} account for heat exchange with the surrounding air:

Rsi=0.13 m2⋅K/W,Rse=0.04 m2⋅K/WR_{si} = 0.13 \text{ m}^2\text{·K/W}, \quad R_{se} = 0.04 \text{ m}^2\text{·K/W}

Total thermal resistance. The assembly resistance is:

Rt=Rsi+∑i=1nRi+RseR_t = R_{si} + \sum_{i=1}^n R_i + R_{se}

Temperature at layer interfaces. For indoor temperature TinT_{in} and outdoor temperature ToutT_{out}, temperature at each interface T(x)T(x) is proportional to the cumulative thermal resistance from the inner surface:

T(x)=Tin−(Tin−Tout)⋅Rcum(x)RtT(x) = T_{in} - (T_{in} - T_{out}) \cdot \frac{R_{cum}(x)}{R_t}

where Rcum(x)R_{cum}(x) is cumulative thermal resistance from the indoor environment to position xx.

Saturation vapor pressure

At each point, the temperature T(x)T(x) determines the maximum water-vapor pressure in the pore air without condensation, the saturation pressure Esat(T(x))E_{sat}(T(x)) in Pa. The calculator uses a standard temperature-dependent saturation function.

Water-vapor partial pressure

Partial pressure at the boundaries. Indoor and outdoor partial pressures are calculated from relative humidity φ\varphi and saturation pressure at the corresponding temperature:

ein=φin100⋅Esat(Tin)e_{in} = \frac{\varphi_{in}}{100} \cdot E_{sat}(T_{in}) eout=φout100⋅Esat(Tout)e_{out} = \frac{\varphi_{out}}{100} \cdot E_{sat}(T_{out})

Diffusion resistance of a layer. For each layer, vapor diffusion resistance is calculated from thickness did_i and vapor permeability δi\delta_i:

Zi=diδiZ_i = \frac{d_i}{\delta_i}

where δi\delta_i is entered in mg/(m·h·Pa), so ZiZ_i is in (m²·h·Pa)/mg.

Surface diffusion resistances. Constant additions account for boundary air layers at the assembly surfaces:

Zsi=0.027 (m2⋅h⋅Pa)/mg,Zse=0.013 (m2⋅h⋅Pa)/mgZ_{si} = 0.027 \text{ (m}^2\text{·h·Pa)/mg}, \quad Z_{se} = 0.013 \text{ (m}^2\text{·h·Pa)/mg}

Total vapor diffusion resistance:

Ztot=Zsi+∑i=1nZi+ZseZ_{tot} = Z_{si} + \sum_{i=1}^n Z_i + Z_{se}

Distribution through the assembly. Actual partial pressure e(x)e(x) at each interface is interpolated linearly according to the fraction of cumulative diffusion resistance:

e(x)=ein−(ein−eout)⋅Zcum(x)Ztote(x) = e_{in} - (e_{in} - e_{out}) \cdot \frac{Z_{cum}(x)}{Z_{tot}}

Condensation criterion

Water vapor may condense at any point if actual partial pressure e(x)e(x) is greater than or equal to saturation pressure at the same temperature:

e(x)≥Esat(T(x))e(x) \ge E_{sat}(T(x))

Any part of the assembly where this condition is met is marked as a possible condensation zone.

02 / Frequently asked questions

What does the possible condensation zone on the chart mean?

It is a part of the assembly where calculated water-vapor partial pressure is greater than or equal to saturation pressure at that temperature (e≥Esate \ge E_{sat}). Air in the material pores is saturated with moisture there, so vapor may condense into liquid water.

Why look at temperature and partial pressure together?

Moisture condensation depends on the balance between heat and vapor. Wall temperature determines the maximum saturation pressure EsatE_{sat} (red curve), while vapor permeability and layer thickness determine actual vapor pressure ee (green curve). Comparing both curves helps assess whether the assembly remains dry.

Why does condensation risk often occur near the cold side?

Near the outside surface, wall temperature falls and saturation pressure EsatE_{sat} drops sharply. If inner layers allow vapor through while outer layers resist it, actual partial pressure ee falls more slowly than EsatE_{sat}, and the curves can cross.

Is this calculation fully accurate for a real house?

The calculator uses a simplified steady-state Glaser-type method. It is useful for quickly comparing wall or roof build-ups. Real temperature and humidity fluctuate, and wind, sun, and wind-driven rain affect the assembly; transient methods such as EN 15026 model these effects more accurately.

How can I reduce condensation inside a wall?

A common design principle is for vapor permeability in a multilayer wall to increase from inside to outside, while thermal resistance increases toward the exterior. This helps vapor escape outdoors instead of becoming trapped in cold parts of the assembly.